TV Power Runbook

Operational runbook for Phase 1 TV power coordination using MQTT power intent plus local HDMI-CEC fallback.

Scope

This runbook covers:

  • POWER_CONTROL_MODE rollout
  • canary validation
  • expected log signatures
  • rollback
  • common failure checks

Contract reference:

Topics and Runtime Files

Phase 1 topic:

  • infoscreen/groups/{group_id}/power/intent

Telemetry topic:

  • infoscreen/{client_id}/power/state

Runtime files:

  • src/power_intent_state.json
  • src/power_state.json
  • src/current_process_health.json

Power Control Modes

  • local: ignore MQTT intent and use local event-time CEC logic.
  • hybrid: prefer fresh MQTT intent and fall back to local timing when missing, stale, or invalid.
  • mqtt: MQTT intent is authoritative; stale or missing intent triggers safe delayed-off behavior.

Recommended rollout path:

  1. Start with local.
  2. Canary with hybrid.
  3. Roll out hybrid fleet-wide after stable observation.
  4. Use mqtt only if you explicitly want strict server authority.

Gate 1: Local Mode

Set in .env:

POWER_CONTROL_MODE=local

Expected startup log signature:

[INFO] Power control mode: local

Expected behavior:

  • No MQTT power intent application.
  • Existing CEC behavior remains unchanged.

Gate 2: Hybrid Canary

On one client or one canary group:

POWER_CONTROL_MODE=hybrid
./scripts/restart-all.sh

Expected startup logs:

[INFO] Power state service thread started
[INFO] Subscribed to power intent topic: infoscreen/groups/<id>/power/intent
[INFO] Power control mode: hybrid

Valid ON Intent

Expected sequence:

[INFO] Power intent accepted: id=<uuid> desired_state=on reason=active_event ...
[INFO] Applying MQTT power intent ON id=<uuid> reason=active_event
[INFO] TV turned ON successfully
[INFO] Power state published: state=on source=mqtt_intent result=ok

Valid OFF Intent

Expected sequence:

[INFO] Power intent accepted: id=<uuid> desired_state=off reason=no_active_event ...
[INFO] Applying MQTT power intent OFF id=<uuid> reason=no_active_event
[INFO] Power state published: state=off source=mqtt_intent result=ok

Expired Intent

Expected rejection:

[WARNING] Rejected power intent: intent expired

Malformed Intent

Expected rejection:

[WARNING] Rejected power intent: missing required field: intent_id

Retained Clear

When you clear the retained topic, the broker delivers an empty payload.

Expected log:

[INFO] Power intent retained message cleared (empty payload)

This is normal and should not be treated as a parse error.

Validation Commands

Use:

./scripts/test-power-intent.sh
./scripts/test-hdmi-cec.sh

Useful test-power-intent paths:

  • Option 1: publish valid ON intent.
  • Option 2: publish valid OFF intent.
  • Option 3: publish stale intent.
  • Option 4: publish malformed intent.
  • Option 5: clear retained topic with an empty retained payload.
  • Option 6: inspect runtime JSON files.
  • Option 8: subscribe to the power-state topic.

Useful manual checks:

tail -f logs/display_manager.log src/simclient.log
cat src/power_intent_state.json
cat src/power_state.json
cat src/current_process_health.json

Rollback

To leave canary mode:

POWER_CONTROL_MODE=local
./scripts/restart-all.sh

Expected result:

  • MQTT power intent handling becomes inactive.
  • Local CEC fallback remains in place.

Fleet Rollout Gate

Roll out hybrid more widely only after:

  • zero unintended TV-off events between adjacent events,
  • valid ON/OFF actions apply cleanly,
  • duplicate refreshes are logged as result=skipped,
  • stale and malformed intents are rejected without side effects,
  • retained clear events no longer produce noisy warnings.

Suggested observation window:

  • at least 7 days on a canary client or canary group.

Common Symptoms

Symptom Check Likely Action
Intent never arrives src/power_intent_state.json missing or invalid Check broker connectivity and group assignment
intent expired appears repeatedly client clock and server publish cadence verify NTP and server refresh interval
TV turns off between adjacent events src/power_state.json shows local_fallback or stale intent at transition inspect server timing and boundary coverage
Repeated power state publishes with skipped duplicate intent refreshes only normal dedupe behavior
Clear retained intent logs warning old code path still running restart services and verify latest code

Dashboard Observability

src/current_process_health.json includes a power_control block similar to:

"power_control": {
  "mode": "hybrid",
  "source": "mqtt_intent",
  "last_intent_id": "4a7fe3bc-...",
  "last_action": "on",
  "last_power_at": "2026-04-01T06:00:05Z"
}

This is the fastest local check for what the display manager last did and why.