# Screenshot capture behavior # Set to 1 to force captures even when no display is active (useful for testing) # In production, prefer 0 so captures only occur when a presentation/video/webpage is running SCREENSHOT_ALWAYS=0 # Infoscreen Client Configuration Template # Copy this file to .env and adjust values for your setup # Environment (set for small prod-like test) # IMPORTANT: CEC TV control is automatically DISABLED when ENV=development # to avoid constantly switching the TV on/off during testing. # Set to 'production' to enable automatic CEC TV control. ENV=development # development | production DEBUG_MODE=0 # 1 to enable debug mode LOG_LEVEL=INFO # DEBUG | INFO | WARNING | ERROR # MQTT Broker Configuration MQTT_BROKER= # Change to your MQTT server IP MQTT_PORT=1883 # Timing Configuration (quieter intervals for productive test) HEARTBEAT_INTERVAL=60 # Heartbeat frequency in seconds SCREENSHOT_INTERVAL=180 # Screenshot transmission (simclient) SCREENSHOT_CAPTURE_INTERVAL=180 # Screenshot capture (display_manager) DISPLAY_CHECK_INTERVAL=15 # Display Manager event check frequency in seconds # File/API Server (used to download presentation files) # By default, the client rewrites incoming file URLs that point to 'server' to this host. # If not set, FILE_SERVER_HOST defaults to the same host as MQTT_BROKER. # You can also set FILE_SERVER_BASE_URL (e.g., http://192.168.1.10:8000) to override entirely. FILE_SERVER_HOST= # optional: e.g., 192.168.43.100 FILE_SERVER_PORT=8000 # default port for API server FILE_SERVER_SCHEME=http # http or https # FILE_SERVER_BASE_URL= # optional: takes precedence over the above when set # HDMI-CEC TV Control (optional) # Automatically turn TV on/off based on event scheduling # NOTE: CEC is automatically DISABLED when ENV=development to avoid constantly switching TV on/off during testing CEC_ENABLED=true # Enable automatic TV power control in production (true/false) CEC_DEVICE=0 # Target CEC device (TV, 0, etc.) CEC_TURN_OFF_DELAY=30 # Seconds to wait before turning off TV after last event ends CEC_POWER_ON_WAIT=5 # Seconds to wait after power ON command (for TV to boot up) CEC_POWER_OFF_WAIT=5 # Seconds to wait after power OFF command (increased for slower TVs) # TV Power Intent (MQTT-based coordinated power control, Phase 1) # Controls how the display manager decides whether to use local CEC or server-issued intent. # local — ignore MQTT intents; all power decisions are local (safe default for rollout) # hybrid — prefer MQTT intent when present and valid; fall back to local CEC if not # mqtt — MQTT intent is authoritative; local CEC only fires as last-resort guard # See README.md "TV Power Intent — Rollout Runbook" before changing from 'local'. POWER_CONTROL_MODE=local # local | hybrid | mqtt # Optional: MQTT authentication (if your broker requires username/password) #MQTT_USERNAME= #MQTT_PASSWORD= # Optional TLS settings (if using secure MQTT) #MQTT_TLS_CA_CERT= #MQTT_TLS_CERT= #MQTT_TLS_KEY= # Notes: # - Keep actual secrets and host-specific values in a local .env file that is NOT committed. # - This template is safe to check into version control.